Overview
Quick Details
Place of Origin:
Russian Federation
Brand Name:
ELAMED
Model Number:
TVGD-02
Supply Ability
Supply Ability:
100 Carton/Cartons per Month
Packaging & Delivery
Packaging Details
box and mail the package
Port
IZHEVSK
Lead Time :
10-14

 


Advantages TVGD-02:

The speed and accuracy of the measurement (especially in mass examinations: clinical examination, examination etc.)
No need for extra consumables.
The presence of two scales measuring the true IOP and tonometric.
The ability of self-control, which have no analogues.
The ability to measure as the sclera and the cornea (through the eyelid), whereas in other devices the measurement is only valid at certain points.
Less risk of infection when measuring IOP through the eyelidDesigned for measuring. tonometric true intraocular pressure through the eyelid in adults and children.
Has two modes of measuring intraocular pressure (IOP):
measurement mode tonometric IOP (tonometer Maklakova scale) the main scale of evaluation of IOP Russian ophthalmology.
mode measurement of true IOP (scale of Goldmann tonometer) – the global rating scale IOP
This feature TVGD-02 makes it interesting and understandable to both domestic and foreign ophthalmologists.
Is a means of measurement, medical devices, approved for use in the home.

Parameters:
The range of indications of intraocular pressure (IOP) (Goldmann), mm.RT.St. - from 5 to 60
The measurement range of the intraocular pressure (IOP) (Goldmann), mm.RT.St. - from 7 to 50
Limits of permissible absolute error of measurement of intraocular pressure (IOP) (Goldmann), mm.RT.St., in the range from 7 to 23 mm RT.St. - ±2
Limits of permissible absolute error of measurement of intraocular pressure (IOP) (Goldmann), mm.RT.St., in the range above 23 mm Hg.St. - ±5
The modes of measurement of IOP by Goldmann
The modes of measurement of IOP by Maklakov
Time of IOP measurement, sec - 2
Display type - LCD
The power supply voltage, 2-3,3
The current consumption in the measurement mode, not more, mA - 100
Digital display - Yes
Character display modes - Yes
A symbolic indication of the battery - Yes
A symbolic indication of readiness for measurement - Yes
Character error indication - Yes
Sound indicator - Yes
 
Equipment:
Tonometer with cap – 1 PC.
Control device – 1 PC.
Case – 1 PC.
The battery AAAA 1.5 V – 2 PCs.
Laser (CD) disk with educational film – 1 PCs.
Verification procedure MP 98.D4-13 – 1 PC.